<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Hydrogen-FC Ltd.</title>
	<atom:link href="http://www.hydrogen-fc.com/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.hydrogen-fc.com</link>
	<description>Automation and Global Partnerships for Hydrogen Power</description>
	<lastBuildDate>Tue, 31 Aug 2010 00:16:53 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.0.1</generator>
		<item>
		<title>Modbus RTU between PLC K120S and VSD Altivar-31 &amp; iG5A</title>
		<link>http://www.hydrogen-fc.com/modbus-rturs-485-plc-k120s-to-vsd-altivar-31-ig5a/</link>
		<comments>http://www.hydrogen-fc.com/modbus-rturs-485-plc-k120s-to-vsd-altivar-31-ig5a/#comments</comments>
		<pubDate>Fri, 26 Mar 2010 17:05:06 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[LS Industrial Systems]]></category>
		<category><![CDATA[Schneider Electric]]></category>
		<category><![CDATA[Modbus]]></category>
		<category><![CDATA[PLC/PAC]]></category>

		<guid isPermaLink="false">http://www.hydrogen-fc.com/?p=621</guid>
		<description><![CDATA[On these case, we build system with PLC K120S from LS Industrial Systems as Master device and VSD (Variable Speed Drive) Altivar-31 from Schneider Electric as 1st Slave device and iG5A from LS Industrial Systems as 2nd Slave Device. All communication between Master and Slave device performed by Modbus RTU protocol. PLC K120S with K7M-DR20U [...]]]></description>
			<content:encoded><![CDATA[<p style="text-align: justify;"><a href="http://www.hydrogen-fc.com/wp-content/uploads/2010/03/K80SK120S.jpg" rel="thumbnail"><img class="alignleft size-thumbnail wp-image-736" style="margin: 5px; border: 1px solid black;" title="K80SK120S" src="http://www.hydrogen-fc.com/wp-content/uploads/2010/03/K80SK120S-250x250.jpg" alt="" width="250" height="250" /></a>On these case, we build system with PLC K120S from <a href="http://eng.lsis.biz/" target="_blank">LS Industrial Systems</a> as Master device and VSD (Variable Speed Drive) Altivar-31 from <a href="http://www.schneider-electric.com/" target="_blank">Schneider Electric</a> as 1st Slave device and iG5A from <a href="http://eng.lsis.biz/" target="_blank">LS Industrial Systems</a> as 2nd Slave Device. All communication between Master and Slave device performed by Modbus RTU protocol.</p>
<p style="text-align: justify;">PLC K120S with K7M-DR20U type is low price PLC with powerful built-in functions, like : PID function, Modbus RTU protocol, High Speed Counter (HSC), Pulse Output. Otherwise, the disadvantage of PLC K120S is could not processing floating data. All analog data will processed using integer format.</p>
<p style="text-align: justify;">Goal target on this case is PLC K120S could set the reference frequency, acceleration, deceleration and monitor current value of output frequency, output current, output voltage and output power from each VSD.<span id="more-621"></span></p>
<p style="text-align: justify;">There is a little trick when using modbus function on PLC K120S ladder programming. That is PLC K120S could not send/receive multiple parameter from/to slave device within same time. There will be occuring error communication. Error communication also occuring when PLC K120S request data to multiple slave devices within same time. We attach below the little trick to resolve that issue.</p>
<p style="text-align: center;"><object classid="clsid:d27cdb6e-ae6d-11cf-96b8-444553540000" width="600" height="494" codebase="http://download.macromedia.com/pub/shockwave/cabs/flash/swflash.cab#version=6,0,40,0"><param name="src" value="http://www.youtube.com/v/4RWEcNxD-Qg" /><embed type="application/x-shockwave-flash" width="600" height="494" src="http://www.youtube.com/v/4RWEcNxD-Qg"></embed></object></p>
<p style="text-align: justify;"><a href="http://www.hydrogen-fc.com/wp-content/uploads/2010/03/AFPX-C30.jpg" rel="thumbnail"><img class="alignleft size-thumbnail wp-image-744" style="margin: 5px; border: 1px solid black;" title="AFPX-C30" src="http://www.hydrogen-fc.com/wp-content/uploads/2010/03/AFPX-C30-250x250.jpg" alt="" width="250" height="250" /></a>We also develop similar system using PLC <a href="http://pewa.panasonic.com/acsd/" target="_blank">Panasonic</a>. Our system using PLC FPX Series from <a href="http://pewa.panasonic.com/acsd/" target="_blank">Panasonic</a> as Master device and 2 units VSD iG5A from <a href="http://eng.lsis.biz/" target="_blank">LS Industrial Systems</a> as Slave device. There is no built-in RS-485 port on PLC FPX Series, so we need add-on communication cassette AFPX-COM3 to perform Modbus RTU communication. On these system, PLC FPX Series also needed similar ladder programming method like on PLC K120S.</p>
<p style="text-align: justify;">We got last confirmation from the end-users that all above design are powerful system. Please fell free to develop your system by using our experiences.</p>
<p style="text-align: center;">
<p style="text-align: justify;">
]]></content:encoded>
			<wfw:commentRss>http://www.hydrogen-fc.com/modbus-rturs-485-plc-k120s-to-vsd-altivar-31-ig5a/feed/</wfw:commentRss>
		<slash:comments>2</slash:comments>
		</item>
		<item>
		<title>Modbus TCP between HMI Ifix5.0 and Flow Computer OMNI6000</title>
		<link>http://www.hydrogen-fc.com/modbus-tcp-protocol-between-omni-6000-and-ifix-5-0/</link>
		<comments>http://www.hydrogen-fc.com/modbus-tcp-protocol-between-omni-6000-and-ifix-5-0/#comments</comments>
		<pubDate>Thu, 01 Oct 2009 17:23:52 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[GE Intelligent Platforms]]></category>
		<category><![CDATA[OMNI Flow Computers]]></category>
		<category><![CDATA[HMI/SCADA]]></category>
		<category><![CDATA[Modbus]]></category>

		<guid isPermaLink="false">http://www.hydrogen-fc.com/?p=124</guid>
		<description><![CDATA[Our previous article had explained how to configuring Modbus TCP protocol between HMI Ifix5.0 and PLC VersaMax40. So that on these article we just explain how to create register blocks and few setup on Modbus Driver v.7.42 Ifix5.0 so that HMI Ifix5.0 as Client device could send/receive data from Flow Computer OMNI6000 as Server device. [...]]]></description>
			<content:encoded><![CDATA[<p style="text-align: justify;"><img class="alignleft size-full wp-image-757" style="margin: 5px; border: 1px solid black;" title="omni3k6k" src="http://www.hydrogen-fc.com/wp-content/uploads/2009/10/omni3k6k.jpg" alt="" width="225" height="171" />Our previous article had explained how to configuring Modbus TCP protocol between HMI Ifix5.0 and PLC VersaMax40. So that on these article we just explain how to create register blocks and few setup on Modbus Driver v.7.42 Ifix5.0 so that HMI Ifix5.0 as Client device could send/receive data from Flow Computer OMNI6000 as Server device.</p>
<p style="text-align: justify;">OMNI6000 is latest Flow Computer from <a href="http://www.omniflow.com/products.aspx" target="_blank">OMNIFLOW Inc</a>. OMNI6000 suitable to be used as deterministic electronic flow/energy correction on metering measurement of crude oils, refined products, NGLs, LPGs, ethylene, propylene, natural gas, and specially gases, such as Oxygen, Nytrogen, Hydrogen, Water, and Carbon Dioxide. OMNI6000 suitable to be used for Orifice Plate or Turbin Meter metering system.<span id="more-124"></span></p>
<table style="border-collapse: collapse; width: 497pt;" border="0" cellspacing="0" cellpadding="0" width="662">
<col style="width: 16pt;" width="21"></col>
<col style="width: 233pt;" width="310"></col>
<col style="width: 8pt;" width="11"></col>
<col style="width: 48pt;" width="64"></col>
<col style="width: 192pt;" width="256"></col>
<tbody>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt; width: 305pt;" colspan="4" width="406" height="17"><strong>Modbus Register of Current Datetime</strong></td>
<td style="width: 192pt;" rowspan="17" width="256" valign="top"><a href="http://www.hydrogen-fc.com/wp-content/uploads/2009/09/Data-Block-Datetime.PNG" rel="thumbnail"><img class="alignright size-thumbnail wp-image-476" style="border: 1px solid black;" title="Data Block - Datetime" src="http://www.hydrogen-fc.com/wp-content/uploads/2009/09/Data-Block-Datetime-250x250.PNG" alt="Data Block - Datetime" width="250" height="250" /></a></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Current &#8211; Hour</td>
<td>:</td>
<td>403868</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Current &#8211; Minute</td>
<td>:</td>
<td>403869</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Current &#8211; Second</td>
<td>:</td>
<td>403870</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Current &#8211; Month</td>
<td>:</td>
<td>403871</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Current &#8211; Day of Month</td>
<td>:</td>
<td>403872</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Current &#8211; Year</td>
<td>:</td>
<td>403873</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Current &#8211; Day of Week</td>
<td>:</td>
<td>403874</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td colspan="3"><em><strong>Advanced Data Block Settings</strong></em></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Size of Registers</td>
<td>:</td>
<td>2 Bytes</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Bytes</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Long Words</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Words</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Accept Unsolited Messages</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Disable Output</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Enable Block Writes</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Enable Latch Data</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" colspan="4" height="17"><strong>Modbus Register of   AGA 8 &#8211; 1994/1992 Components Override Value</strong></td>
<td rowspan="37" valign="top"><a href="http://www.hydrogen-fc.com/wp-content/uploads/2009/09/Data-Block-AGA8.PNG" rel="thumbnail"><img class="alignright size-thumbnail wp-image-478" style="border: 1px solid black;" title="Data Block - AGA8" src="http://www.hydrogen-fc.com/wp-content/uploads/2009/09/Data-Block-AGA8-250x250.PNG" alt="Data Block - AGA8" width="250" height="250" /></a></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Product #1 &#8211; Mol % &#8211; Methane</td>
<td>:</td>
<td>417231</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Product #1 &#8211; Mol % &#8211; Nitrogen</td>
<td>:</td>
<td>417232</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Product #1 &#8211; Mol % &#8211; Carbon Dioxide</td>
<td>:</td>
<td>417233</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Product #1 &#8211; Mol % &#8211; Ethane</td>
<td>:</td>
<td>417234</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Product #1 &#8211; Mol % &#8211; Propane</td>
<td>:</td>
<td>417235</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Product #1 &#8211; Mol % &#8211; Water</td>
<td>:</td>
<td>417236</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Product #1 &#8211; Mol % &#8211; Hydrogen Sulfide</td>
<td>:</td>
<td>417237</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Product #1 &#8211; Mol % &#8211; Hydrogen</td>
<td>:</td>
<td>417238</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Product #1 &#8211; Mol % &#8211; Carbon Monoxide</td>
<td>:</td>
<td>417239</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Product #1 &#8211; Mol % &#8211; Oxygen</td>
<td>:</td>
<td>417240</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Product #1 &#8211; Mol % &#8211; i-Butane</td>
<td>:</td>
<td>417241</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Product #1 &#8211; Mol % &#8211; n-Butane</td>
<td>:</td>
<td>417242</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Product #1 &#8211; Mol % &#8211; i-Pentane</td>
<td>:</td>
<td>417243</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Product #1 &#8211; Mol % &#8211; n-Pentane</td>
<td>:</td>
<td>417244</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Product #1 &#8211; Mol % &#8211; n-Hexane</td>
<td>:</td>
<td>417245</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Product #1 &#8211; Mol % &#8211; n-Heptane</td>
<td>:</td>
<td>417246</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Product #1 &#8211; Mol % &#8211; n-Octane</td>
<td>:</td>
<td>417247</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Product #1 &#8211; Mol % &#8211; n-Nonane</td>
<td>:</td>
<td>417248</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Product #1 &#8211; Mol % &#8211; n-Decane</td>
<td>:</td>
<td>417249</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Product #1 &#8211; Mol % &#8211; Helium</td>
<td>:</td>
<td>417250</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Product #1 &#8211; Mol % &#8211; Argon</td>
<td>:</td>
<td>417251</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Product #1 &#8211; Viscosity</td>
<td>:</td>
<td>417252</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Product #1 &#8211; Isentropic Exponent K</td>
<td>:</td>
<td>417253</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Product #1 &#8211; Heating Value</td>
<td>:</td>
<td>417254</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Product #1 &#8211; Reference Specific Gravity</td>
<td>:</td>
<td>417255</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Product #1 &#8211; Reference Density</td>
<td>:</td>
<td>417256</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Product #1 &#8211; Water Content</td>
<td>:</td>
<td>417257</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td colspan="3"><em><strong>Advanced Data Block Settings</strong></em></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Size of Registers</td>
<td>:</td>
<td>4 Bytes</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Bytes</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Long Words</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Words</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="page-break-before: always; height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Accept Unsolited Messages</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Disable Output</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Enable Block Writes</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Enable Latch Data</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" colspan="4" height="17"><em><strong>Modbus Register of   Gas Chromatograph Data &amp; Auxilliary Parameter</strong></em></td>
<td rowspan="60" valign="top"><a href="http://www.hydrogen-fc.com/wp-content/uploads/2009/09/Data-Block-GC_AUX.PNG" rel="thumbnail"><img class="alignright size-thumbnail wp-image-480" style="border: 1px solid black;" title="Data Block - GC_AUX" src="http://www.hydrogen-fc.com/wp-content/uploads/2009/09/Data-Block-GC_AUX-250x250.PNG" alt="Data Block - GC_AUX" width="250" height="250" /></a></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #1</td>
<td>:</td>
<td>417351</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #2</td>
<td>:</td>
<td>417352</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #3</td>
<td>:</td>
<td>417353</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #4</td>
<td>:</td>
<td>417354</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #5</td>
<td>:</td>
<td>417355</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #6</td>
<td>:</td>
<td>417356</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #7</td>
<td>:</td>
<td>417357</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #8</td>
<td>:</td>
<td>417358</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #9</td>
<td>:</td>
<td>417359</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #10</td>
<td>:</td>
<td>417360</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #11</td>
<td>:</td>
<td>417361</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #12</td>
<td>:</td>
<td>417362</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #13</td>
<td>:</td>
<td>417363</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #14</td>
<td>:</td>
<td>417364</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #15</td>
<td>:</td>
<td>417365</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #16</td>
<td>:</td>
<td>417366</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #17</td>
<td>:</td>
<td>417367</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #18</td>
<td>:</td>
<td>417368</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #19</td>
<td>:</td>
<td>417369</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #20</td>
<td>:</td>
<td>417370</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #21</td>
<td>:</td>
<td>417371</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #22</td>
<td>:</td>
<td>417372</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #23</td>
<td>:</td>
<td>417373</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #24</td>
<td>:</td>
<td>417374</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #25 (Actual BTU)</td>
<td>:</td>
<td>417375</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #26 (Dry BTU)</td>
<td>:</td>
<td>417376</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #27 (Specific Gravity)</td>
<td>:</td>
<td>417377</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #28</td>
<td>:</td>
<td>417378</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #29</td>
<td>:</td>
<td>417379</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Analyzer Component #30</td>
<td>:</td>
<td>417380</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Auxilliary Input #1 &#8211; Low Limit</td>
<td>:</td>
<td>417381</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Auxilliary Input #1 &#8211; High Limit</td>
<td>:</td>
<td>417382</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Auxilliary Input #1 &#8211; Override Value</td>
<td>:</td>
<td>417383</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Auxilliary Input #1 &#8211; @ 4mA</td>
<td>:</td>
<td>417384</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Auxilliary Input #1 &#8211; @ 20 mA</td>
<td>:</td>
<td>417385</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Auxilliary Input #2 &#8211; Low Limit</td>
<td>:</td>
<td>417386</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Auxilliary Input #2 &#8211; High Limit</td>
<td>:</td>
<td>417387</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Auxilliary Input #2 &#8211; Override Value</td>
<td>:</td>
<td>417388</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Auxilliary Input #2 &#8211; @ 4mA</td>
<td>:</td>
<td>417389</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Auxilliary Input #2 &#8211; @ 20 mA</td>
<td>:</td>
<td>417390</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Auxilliary Input #3 &#8211; Low Limit</td>
<td>:</td>
<td>417391</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Auxilliary Input #3 &#8211; High Limit</td>
<td>:</td>
<td>417392</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Auxilliary Input #3 &#8211; Override Value</td>
<td>:</td>
<td>417393</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Auxilliary Input #3 &#8211; @ 4mA</td>
<td>:</td>
<td>417394</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Auxilliary Input #3 &#8211; @ 20 mA</td>
<td>:</td>
<td>417395</td>
</tr>
<tr style="page-break-before: always; height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Auxilliary Input #4 &#8211; Low Limit</td>
<td>:</td>
<td>417396</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Auxilliary Input #4 &#8211; High Limit</td>
<td>:</td>
<td>417397</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Auxilliary Input #4 &#8211; Override Value</td>
<td>:</td>
<td>417398</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Auxilliary Input #4 &#8211; @ 4mA</td>
<td>:</td>
<td>417399</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Auxilliary Input #4 &#8211; @ 20 mA</td>
<td>:</td>
<td>417400</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td colspan="3"><em><strong>Advanced Data Block Settings</strong></em></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Size of Registers</td>
<td>:</td>
<td>4 Bytes</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Bytes</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Long Words</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Words</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Accept Unsolited Messages</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Disable Output</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Enable Block Writes</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Enable Latch Data</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" colspan="4" height="17"><strong>Modbus Register of   Auxilliary Live Value</strong></td>
<td rowspan="14" valign="top"><a href="http://www.hydrogen-fc.com/wp-content/uploads/2009/09/Data-Block-AUX.PNG" rel="thumbnail"><img class="alignright size-thumbnail wp-image-484" style="border: 1px solid black;" title="Data Block - AUX" src="http://www.hydrogen-fc.com/wp-content/uploads/2009/09/Data-Block-AUX-250x250.PNG" alt="Data Block - AUX" width="250" height="250" /></a></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Auxilliary Input #1</td>
<td>:</td>
<td>407810</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Auxilliary Input #2</td>
<td>:</td>
<td>407811</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Auxilliary Input #3</td>
<td>:</td>
<td>407812</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Auxilliary Input #4</td>
<td>:</td>
<td>407813</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td colspan="3"><em><strong>Advanced Data Block Settings</strong></em></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Size of Registers</td>
<td>:</td>
<td>4 Bytes</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Bytes</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Long Words</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Words</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Accept Unsolited Messages</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Disable Output</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Enable Block Writes</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Enable Latch Data</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" colspan="4" height="17"><strong>Modbus Register of   Stream A Live Value</strong></td>
<td rowspan="18" valign="top"><a href="http://www.hydrogen-fc.com/wp-content/uploads/2009/10/Data-Block-Stream-A.PNG" rel="thumbnail"><img class="alignright size-thumbnail wp-image-506" style="border: 1px solid black;" title="Data Block - Stream A" src="http://www.hydrogen-fc.com/wp-content/uploads/2009/10/Data-Block-Stream-A-250x250.PNG" alt="Data Block - Stream A" width="250" height="250" /></a></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Flow Rate &#8211; Gross (MACF/hr or m3/hr)</td>
<td>:</td>
<td>407102</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Flow Rate &#8211; Net (MSCF/hr or m3/hr)</td>
<td>:</td>
<td>407103</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Flow Rate &#8211; Mass (Klb/hr or ton/hr)</td>
<td>:</td>
<td>407104</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Flow Rate &#8211; Energy (MMBTU/hr or GJ/hr)</td>
<td>:</td>
<td>407105</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Temperature</td>
<td>:</td>
<td>407106</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Pressure</td>
<td>:</td>
<td>407107</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Orifice &#8211; Diameter</td>
<td>:</td>
<td>407113</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Meter Tube Diameter</td>
<td>:</td>
<td>407118</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td colspan="3"><em><strong>Advanced Data Block Settings</strong></em></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Size of Registers</td>
<td>:</td>
<td>4 Bytes</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Bytes</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Long Words</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Words</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Accept Unsolited Messages</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Disable Output</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Enable Block Writes</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Enable Latch Data</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" colspan="4" height="17"><strong>Modbus Register of   Stream B Live Value</strong></td>
<td rowspan="18" valign="top"><a href="http://www.hydrogen-fc.com/wp-content/uploads/2009/10/Data-Block-Stream-B.PNG" rel="thumbnail"><img class="alignright size-thumbnail wp-image-508" style="border: 1px solid black;" title="Data Block - Stream B" src="http://www.hydrogen-fc.com/wp-content/uploads/2009/10/Data-Block-Stream-B-250x250.PNG" alt="Data Block - Stream B" width="250" height="250" /></a></td>
</tr>
<tr style="page-break-before: always; height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Flow Rate &#8211; Gross (MACF/hr or m3/hr)</td>
<td>:</td>
<td>407202</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Flow Rate &#8211; Net (MSCF/hr or m3/hr)</td>
<td>:</td>
<td>407203</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Flow Rate &#8211; Mass (Klb/hr or ton/hr)</td>
<td>:</td>
<td>407204</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Flow Rate &#8211; Energy (MMBTU/hr or GJ/hr)</td>
<td>:</td>
<td>407205</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Temperature</td>
<td>:</td>
<td>407206</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Pressure</td>
<td>:</td>
<td>407207</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Orifice &#8211; Diameter</td>
<td>:</td>
<td>407213</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Meter Tube Diameter</td>
<td>:</td>
<td>407218</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td colspan="3"><em><strong>Advanced Data Block Settings</strong></em></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Size of Registers</td>
<td>:</td>
<td>4 Bytes</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Bytes</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Long Words</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Words</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Accept Unsolited Messages</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Disable Output</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Enable Block Writes</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Enable Latch Data</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" colspan="4" height="17"><strong>Modbus Register of   Transmitter Stream A Parameter</strong></td>
<td rowspan="27" valign="top"><a href="http://www.hydrogen-fc.com/wp-content/uploads/2009/10/Data-Block-FT-TT-PT-Stream-A.PNG" rel="thumbnail"><img class="alignright size-thumbnail wp-image-516" style="border: 1px solid black;" title="Data Block - FT TT PT Stream A" src="http://www.hydrogen-fc.com/wp-content/uploads/2009/10/Data-Block-FT-TT-PT-Stream-A-250x250.PNG" alt="Data Block - FT TT PT Stream A" width="250" height="250" /></a></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Orifice Plate &#8211; Reference Temperature</td>
<td>:</td>
<td>407148</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Meter Tube &#8211; Reference Temperature</td>
<td>:</td>
<td>407151</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Differential Pressure &#8211; Low Limit</td>
<td>:</td>
<td>407153</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Differential Pressure &#8211; High Limit</td>
<td>:</td>
<td>407154</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Differential Pressure &#8211; Override Value</td>
<td>:</td>
<td>407155</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Low Range &#8211; Differential Pressure &#8211; @ 4mA</td>
<td>:</td>
<td>407156</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Low Range &#8211; Differential Pressure &#8211; @ 20mA</td>
<td>:</td>
<td>407157</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Meter Temperature &#8211; Low Limit</td>
<td>:</td>
<td>407164</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Meter Temperature &#8211; High Limit</td>
<td>:</td>
<td>407165</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Meter Temperature &#8211; Override</td>
<td>:</td>
<td>407166</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Meter Temperature &#8211; @ 4mA</td>
<td>:</td>
<td>407167</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Meter Temperature &#8211; @ 20mA</td>
<td>:</td>
<td>407168</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Meter Pressure &#8211; Low Limit</td>
<td>:</td>
<td>407169</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Meter Pressure &#8211; High Limit</td>
<td>:</td>
<td>407170</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Meter Pressure &#8211; Override</td>
<td>:</td>
<td>407171</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Meter Pressure &#8211; @ 4mA</td>
<td>:</td>
<td>407172</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Meter Pressure &#8211; @ 20mA</td>
<td>:</td>
<td>407173</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td colspan="3"><em><strong>Advanced Data Block Settings</strong></em></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Size of Registers</td>
<td>:</td>
<td>4 Bytes</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Bytes</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Long Words</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Words</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Accept Unsolited Messages</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Disable Output</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Enable Block Writes</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Enable Latch Data</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" colspan="4" height="17"><strong>Modbus Register of   Transmitter Stream B Parameter</strong></td>
<td rowspan="27" valign="top"><a href="http://www.hydrogen-fc.com/wp-content/uploads/2009/10/Data-Block-FT-TT-PT-Stream-B.PNG" rel="thumbnail"><img class="alignright size-thumbnail wp-image-517" style="border: 1px solid black;" title="Data Block - FT TT PT Stream B" src="http://www.hydrogen-fc.com/wp-content/uploads/2009/10/Data-Block-FT-TT-PT-Stream-B-250x250.PNG" alt="Data Block - FT TT PT Stream B" width="250" height="250" /></a></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Orifice Plate &#8211; Reference Temperature</td>
<td>:</td>
<td>407248</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Meter Tube &#8211; Reference Temperature</td>
<td>:</td>
<td>407251</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Differential Pressure &#8211; Low Limit</td>
<td>:</td>
<td>407253</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Differential Pressure &#8211; High Limit</td>
<td>:</td>
<td>407254</td>
</tr>
<tr style="page-break-before: always; height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Differential Pressure &#8211; Override Value</td>
<td>:</td>
<td>407255</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Low Range &#8211; Differential Pressure &#8211; @ 4mA</td>
<td>:</td>
<td>407256</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Low Range &#8211; Differential Pressure &#8211; @ 20mA</td>
<td>:</td>
<td>407257</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Meter Temperature &#8211; Low Limit</td>
<td>:</td>
<td>407264</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Meter Temperature &#8211; High Limit</td>
<td>:</td>
<td>407265</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Meter Temperature &#8211; Override</td>
<td>:</td>
<td>407266</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Meter Temperature &#8211; @ 4mA</td>
<td>:</td>
<td>407267</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Meter Temperature &#8211; @ 20mA</td>
<td>:</td>
<td>407268</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Meter Pressure &#8211; Low Limit</td>
<td>:</td>
<td>407269</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Meter Pressure &#8211; High Limit</td>
<td>:</td>
<td>407270</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Meter Pressure &#8211; Override</td>
<td>:</td>
<td>407271</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Meter Pressure &#8211; @ 4mA</td>
<td>:</td>
<td>407272</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Meter Pressure &#8211; @ 20mA</td>
<td>:</td>
<td>407273</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td colspan="3"><em><strong>Advanced Data Block Settings</strong></em></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Size of Registers</td>
<td>:</td>
<td>4 Bytes</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Bytes</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Long Words</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Words</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Accept Unsolited Messages</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Disable Output</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Enable Block Writes</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Enable Latch Data</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" colspan="4" height="17"><strong>Modbus Register of   In Progress Batch, Cumm, Daily Live Value Stream A</strong></td>
<td rowspan="22" valign="top"><a href="http://www.hydrogen-fc.com/wp-content/uploads/2009/10/Data-Block-In-Batch-Day-Stream-A.PNG" rel="thumbnail"><img class="alignright size-thumbnail wp-image-523" style="border: 1px solid black;" title="Data Block - In Batch Day Stream A" src="http://www.hydrogen-fc.com/wp-content/uploads/2009/10/Data-Block-In-Batch-Day-Stream-A-250x250.PNG" alt="Data Block - In Batch Day Stream A" width="250" height="250" /></a></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Batch in Progress &#8211; Gross Totalizer</td>
<td>:</td>
<td>405102</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Batch in Progress &#8211; Net Totalizer</td>
<td>:</td>
<td>405103</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Batch in Progress &#8211; Mass Totalizer</td>
<td>:</td>
<td>405104</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Batch in Progress &#8211; Energy Totalizer</td>
<td>:</td>
<td>405105</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Cummulative in Progress &#8211; Gross Totalizer</td>
<td>:</td>
<td>405106</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Cummulative in Progress &#8211; Net Totalizer</td>
<td>:</td>
<td>405107</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Cummulative in Progress &#8211; Mass Totalizer</td>
<td>:</td>
<td>405108</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Cummulative in Progress &#8211; Energy Totalizer</td>
<td>:</td>
<td>405109</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Today In Progress &#8211; Gross Totalizer</td>
<td>:</td>
<td>405110</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Today In Progress &#8211; Net Totalizer</td>
<td>:</td>
<td>405111</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Today In Progress &#8211; Mass Totalizer</td>
<td>:</td>
<td>405112</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Today In Progress &#8211; Energy Totalizer</td>
<td>:</td>
<td>405113</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td colspan="3"><em><strong>Advanced Data Block Settings</strong></em></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Size of Registers</td>
<td>:</td>
<td>4 Bytes</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Bytes</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Long Words</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Words</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Accept Unsolited Messages</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Disable Output</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Enable Block Writes</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Enable Latch Data</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" colspan="4" height="17"><strong>Modbus Register of   In Progress Batch, Cumm, Daily Live Value Stream B</strong></td>
<td rowspan="22" valign="top"><a href="http://www.hydrogen-fc.com/wp-content/uploads/2009/10/Data-Block-In-Batch-Day-Stream-B.PNG" rel="thumbnail"><img class="alignright size-thumbnail wp-image-524" style="border: 1px solid black;" title="Data Block - In Batch Day Stream B" src="http://www.hydrogen-fc.com/wp-content/uploads/2009/10/Data-Block-In-Batch-Day-Stream-B-250x250.PNG" alt="Data Block - In Batch Day Stream B" width="250" height="250" /></a></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Batch in Progress &#8211; Gross Totalizer</td>
<td>:</td>
<td>405202</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Batch in Progress &#8211; Net Totalizer</td>
<td>:</td>
<td>405203</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Batch in Progress &#8211; Mass Totalizer</td>
<td>:</td>
<td>405204</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Batch in Progress &#8211; Energy Totalizer</td>
<td>:</td>
<td>405205</td>
</tr>
<tr style="page-break-before: always; height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Cummulative in Progress &#8211; Gross Totalizer</td>
<td>:</td>
<td>405206</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Cummulative in Progress &#8211; Net Totalizer</td>
<td>:</td>
<td>405207</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Cummulative in Progress &#8211; Mass Totalizer</td>
<td>:</td>
<td>405208</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Cummulative in Progress &#8211; Energy Totalizer</td>
<td>:</td>
<td>405209</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Today In Progress &#8211; Gross Totalizer</td>
<td>:</td>
<td>405210</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Today In Progress &#8211; Net Totalizer</td>
<td>:</td>
<td>405211</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Today In Progress &#8211; Mass Totalizer</td>
<td>:</td>
<td>405212</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Today In Progress &#8211; Energy Totalizer</td>
<td>:</td>
<td>405213</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td colspan="3"><em><strong>Advanced Data Block Settings</strong></em></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Size of Registers</td>
<td>:</td>
<td>4 Bytes</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Bytes</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Long Words</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Words</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Accept Unsolited Messages</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Disable Output</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Enable Block Writes</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Enable Latch Data</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" colspan="4" height="17"><em><strong>Modbus Register of   In Progress Hourly Live Value Stream A</strong></em></td>
<td rowspan="14" valign="top"><a href="http://www.hydrogen-fc.com/wp-content/uploads/2009/10/Data-Block-In-Hourly-Stream-A.PNG" rel="thumbnail"><img class="alignright size-thumbnail wp-image-527" style="border: 1px solid black;" title="Data Block - In Hourly Stream A" src="http://www.hydrogen-fc.com/wp-content/uploads/2009/10/Data-Block-In-Hourly-Stream-A-250x250.PNG" alt="Data Block - In Hourly Stream A" width="250" height="250" /></a></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>In Progress &#8211; Gross Total for Hour</td>
<td>:</td>
<td>405145</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>In Progress &#8211; Net Total for Hour</td>
<td>:</td>
<td>405146</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>In Progess &#8211; Mas Total for Hour</td>
<td>:</td>
<td>405147</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>IN Progress &#8211; Energy Total for Hour</td>
<td>:</td>
<td>405148</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td colspan="3"><em><strong>Advanced Data Block Settings</strong></em></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Size of Registers</td>
<td>:</td>
<td>4 Bytes</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Bytes</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Long Words</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Words</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Accept Unsolited Messages</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Disable Output</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Enable Block Writes</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Enable Latch Data</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" colspan="4" height="17"><em><strong>Modbus Register of   In Progress Hourly Live Value Stream B</strong></em></td>
<td rowspan="14" valign="top"><a href="http://www.hydrogen-fc.com/wp-content/uploads/2009/10/Data-Block-In-Hourly-Stream-B.PNG" rel="thumbnail"><img class="alignright size-thumbnail wp-image-528" style="border: 1px solid black;" title="Data Block - In Hourly Stream B" src="http://www.hydrogen-fc.com/wp-content/uploads/2009/10/Data-Block-In-Hourly-Stream-B-250x250.PNG" alt="Data Block - In Hourly Stream B" width="250" height="250" /></a></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>In Progress &#8211; Gross Total for Hour</td>
<td>:</td>
<td>405245</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>In Progress &#8211; Net Total for Hour</td>
<td>:</td>
<td>405246</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>In Progess &#8211; Mas Total for Hour</td>
<td>:</td>
<td>402247</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>IN Progress &#8211; Energy Total for Hour</td>
<td>:</td>
<td>405248</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td colspan="3">Advanced Data Block Settings</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Size of Registers</td>
<td>:</td>
<td>4 Bytes</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Bytes</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Long Words</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Words</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Accept Unsolited Messages</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Disable Output</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Enable Block Writes</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Enable Latch Data</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" colspan="4" height="17"><strong>Modbus Register of   Previous, Hour, Cumm Live Value Stream A</strong></td>
<td rowspan="26" valign="top"><a href="http://www.hydrogen-fc.com/wp-content/uploads/2009/10/Data-Block-Pr-Hour-Cumm-Stream-A.PNG" rel="thumbnail"><img class="alignright size-thumbnail wp-image-538" style="border: 1px solid black;" title="Data Block - Pr Hour Cumm Stream A" src="http://www.hydrogen-fc.com/wp-content/uploads/2009/10/Data-Block-Pr-Hour-Cumm-Stream-A-250x250.PNG" alt="Data Block - Pr Hour Cumm Stream A" width="250" height="250" /></a></td>
</tr>
<tr style="page-break-before: always; height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Increment &#8211; Gross Totalizer</td>
<td>:</td>
<td>405171</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Increment &#8211; Net Totalizer</td>
<td>:</td>
<td>405172</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Increment &#8211; Mass Totalizer</td>
<td>:</td>
<td>405173</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Increment &#8211; Energy Totalizer</td>
<td>:</td>
<td>405174</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Previous Hourly &#8211; Gross Total</td>
<td>:</td>
<td>405175</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Previous Hourly &#8211; Net Total</td>
<td>:</td>
<td>405176</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Previous Hourly &#8211; Mass Total</td>
<td>:</td>
<td>405177</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Previous Hourly &#8211; Energy Total</td>
<td>:</td>
<td>405178</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Previous Batch &#8211; Opening Gross</td>
<td>:</td>
<td>405179</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Previous Batch &#8211; Opening Net</td>
<td>:</td>
<td>405180</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Previous Batch &#8211; Opening Mass</td>
<td>:</td>
<td>405181</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Previous Batch &#8211; Opening Energy</td>
<td>:</td>
<td>405182</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Previous Day&#8217;s &#8211; Opening Gross</td>
<td>:</td>
<td>405183</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Previous Day&#8217;s &#8211; Opening Net</td>
<td>:</td>
<td>405184</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Previous Day&#8217;s &#8211; Opening Mass</td>
<td>:</td>
<td>405185</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Previous Day&#8217;s &#8211; Opening Energy</td>
<td>:</td>
<td>405186</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td colspan="3"><em><strong>Advanced Data Block Settings</strong></em></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Size of Registers</td>
<td>:</td>
<td>4 Bytes</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Bytes</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Long Words</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Words</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Accept Unsolited Messages</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Disable Output</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Enable Block Writes</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Enable Latch Data</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" colspan="4" height="17"><strong>Modbus Register of   Previous, Hour, Cumm Live Value Stream B</strong></td>
<td rowspan="26" valign="top"><a href="http://www.hydrogen-fc.com/wp-content/uploads/2009/10/Data-Block-Pr-Hour-Cumm-Stream-B.PNG" rel="thumbnail"><img class="alignright size-thumbnail wp-image-539" style="border: 1px solid black;" title="Data Block - Pr Hour Cumm Stream B" src="http://www.hydrogen-fc.com/wp-content/uploads/2009/10/Data-Block-Pr-Hour-Cumm-Stream-B-250x250.PNG" alt="Data Block - Pr Hour Cumm Stream B" width="250" height="250" /></a></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Increment &#8211; Gross Totalizer</td>
<td>:</td>
<td>405271</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Increment &#8211; Net Totalizer</td>
<td>:</td>
<td>405272</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Increment &#8211; Mass Totalizer</td>
<td>:</td>
<td>405273</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Increment &#8211; Energy Totalizer</td>
<td>:</td>
<td>405274</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Previous Hourly &#8211; Gross Total</td>
<td>:</td>
<td>405275</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Previous Hourly &#8211; Net Total</td>
<td>:</td>
<td>405276</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Previous Hourly &#8211; Mass Total</td>
<td>:</td>
<td>405277</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Previous Hourly &#8211; Energy Total</td>
<td>:</td>
<td>405278</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Previous Batch &#8211; Opening Gross</td>
<td>:</td>
<td>405279</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Previous Batch &#8211; Opening Net</td>
<td>:</td>
<td>405280</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Previous Batch &#8211; Opening Mass</td>
<td>:</td>
<td>405281</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Previous Batch &#8211; Opening Energy</td>
<td>:</td>
<td>405282</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Previous Day&#8217;s &#8211; Opening Gross</td>
<td>:</td>
<td>405283</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Previous Day&#8217;s &#8211; Opening Net</td>
<td>:</td>
<td>405284</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Previous Day&#8217;s &#8211; Opening Mass</td>
<td>:</td>
<td>405285</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Previous Day&#8217;s &#8211; Opening Energy</td>
<td>:</td>
<td>405286</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td colspan="3"><em><strong>Advanced Data Block Settings</strong></em></td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Size of Registers</td>
<td>:</td>
<td>4 Bytes</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Bytes</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Long Words</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Swap Words</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Accept Unsolited Messages</td>
<td>:</td>
<td>TRUE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Disable Output</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Enable Block Writes</td>
<td>:</td>
<td>FALSE</td>
</tr>
<tr style="page-break-before: always; height: 12.75pt;" height="17">
<td style="height: 12.75pt;" height="17"></td>
<td>Enable Latch Data</td>
<td>:</td>
<td>FALSE</td>
</tr>
</tbody>
</table>
]]></content:encoded>
			<wfw:commentRss>http://www.hydrogen-fc.com/modbus-tcp-protocol-between-omni-6000-and-ifix-5-0/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>PID &amp; Alternate Control System</title>
		<link>http://www.hydrogen-fc.com/pid-close-loop-controller/</link>
		<comments>http://www.hydrogen-fc.com/pid-close-loop-controller/#comments</comments>
		<pubDate>Sun, 13 Sep 2009 13:05:19 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Wonderware Invensys]]></category>
		<category><![CDATA[HMI/SCADA]]></category>
		<category><![CDATA[PLC/PAC]]></category>

		<guid isPermaLink="false">http://www.hydrogen-fc.com/?p=450</guid>
		<description><![CDATA[PID (Proportional-Integral-Derivative) controller is control loop feedback mechanism that widely used in control system. PID calculating the error value that generated by difference between feedback Process Value (PV) and Set Point (SP) PID. When error value generating, PID controller adjusting output Measurement Value (MV) to minimize error near to zero value. Let us give some [...]]]></description>
			<content:encoded><![CDATA[<p style="text-align: justify;"><a href="http://www.hydrogen-fc.com/wp-content/uploads/2009/09/PID_PUMP.jpg" rel="thumbnail"><img class="alignleft size-thumbnail wp-image-763" style="margin: 5px; border: 1px solid black;" title="PID_PUMP" src="http://www.hydrogen-fc.com/wp-content/uploads/2009/09/PID_PUMP-250x250.jpg" alt="" width="250" height="250" /></a><a href="http://en.wikipedia.org/wiki/PID_controller" target="_blank">PID (Proportional-Integral-Derivative) controller</a> is control loop feedback mechanism that widely used in control system. PID calculating the error value that generated by difference between feedback Process Value (PV) and Set Point (SP) PID. When error value generating, PID controller adjusting output Measurement Value (MV) to minimize error near to zero value.</p>
<p style="text-align: justify;">Let us give some example PID Controller on Booster Pump application like on the left picture. Feedback Process Value (PV) is Actual Pressure (Bar), Set Point (SP) PID is Set Pressure (Bar), and output Measurement Value (MV) is VSD Reference Frequency (Hz).  This is the mechanism. Whenever the difference between PV &amp; SP negative, PID Controller increasing output MV. Otherwise when the difference between PV &amp; SP positive, PID Controller decreasing output MV. How fast the PID Controller could execute error calculation are depend on cycle speed on each controller and type of PID function.  There are several PID function base on control actions, which are P, I, PI, PD. PI function is widely used for Booster Pump application.<span id="more-450"></span></p>
<p style="text-align: center;"><img class="aligncenter size-full wp-image-457" title="PID" src="http://www.hydrogen-fc.com/wp-content/uploads/2009/09/PID.PNG" alt="" width="579" height="150" /></p>
<p style="text-align: justify;">This is the PID &amp; Alternate control system on Booster Pump application. There are 1 unit Pressure Transmitter,  1 unit PLC and 2 units Booster Pump that controlled by 1 unit VSD. Because of most VSD have PID Controller, we design the PI controller in the VSD. These are the several case :</p>
<ul>
<li style="text-align: justify;">At the first time start PID in VSD with Pump A. VSD adjusting output frequency (Hz) into Pump A so that Actual Pressure (Bar) close to Set Pressure (Bar).</li>
<li style="text-align: justify;">Case 1 : Pump A couldn&#8217;t reach the target of Set Pressure (Bar), then PLC set 50Hz into Pump A and start PID in VSD with Pump B.</li>
<li style="text-align: justify;">Case 2 : Actual Pressure (Bar) is too high so that VSD set 0Hz into Pump B. This case make PLC to stop Pump B and start PID in VSD with Pump A.</li>
<li style="text-align: justify;">Case 3 : Actual Pressure (Bar) still on high pressure so that VSD set 0Hz into Pump A. This case make PLC to stop Pump A. That mean booster Pump A and B on the sleep condition.</li>
<li style="text-align: justify;">Case 4 : Suddenly Actual Pressure (Bar) drop to below Set Pressure (Bar). This case make PLC start PID in VSD with Pump B because of the last running pump before sleep is Pump A. This mechanism important to make sure all pumps have same running hour.</li>
</ul>
<p style="text-align: center;"><object classid="clsid:d27cdb6e-ae6d-11cf-96b8-444553540000" width="640" height="480" codebase="http://download.macromedia.com/pub/shockwave/cabs/flash/swflash.cab#version=6,0,40,0"><param name="quality" value="best" /><param name="scale" value="noborder" /><param name="salign" value="t" /><param name="wmode" value="transparent" /><param name="src" value="http://www.youtube.com/v/aGEKCqmXEYQ" /><param name="align" value="top" /><embed type="application/x-shockwave-flash" width="640" height="480" src="http://www.youtube.com/v/aGEKCqmXEYQ" align="top" wmode="transparent" salign="t" scale="noborder" quality="best"></embed></object></p>
<p style="text-align: justify;">With the PID &amp; Alternate control system, we could just add booster pump without add more VSD  to increase efficiency and capacity on Booster Pump Station. Mostly, Booster Pump Stations are using PID &amp; Alternate control system because it could saving more cost for electrical energy consuption.</p>
<p style="text-align: justify;">All of animation and graphical developed by <a href="http://www.archestra.biz/default.aspx" target="_blank">Wonderware</a> ArchestrA 3.0.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.hydrogen-fc.com/pid-close-loop-controller/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Modbus TCP between HMI Ifix5.0 and PLC VersaMax40</title>
		<link>http://www.hydrogen-fc.com/modbus-tcp-protocol-between-versamax40-and-ifix-5-0/</link>
		<comments>http://www.hydrogen-fc.com/modbus-tcp-protocol-between-versamax40-and-ifix-5-0/#comments</comments>
		<pubDate>Tue, 01 Sep 2009 17:07:28 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[GE Intelligent Platforms]]></category>
		<category><![CDATA[HMI/SCADA]]></category>
		<category><![CDATA[Modbus]]></category>
		<category><![CDATA[PLC/PAC]]></category>

		<guid isPermaLink="false">http://www.hydrogen-fc.com/?p=123</guid>
		<description><![CDATA[VersaMax40 is one kind of VersaMax Micro Plus Controllers from GE Intelligent Platforms that have more enhanced features like : more memory (for boolean, integer, floating data), real time clock (RTC),  optional port for industrial protocol communication, high speed counter (HSC) up to 4 at 100kHz, pulse width modulation (PWM) up to 4 at 65kHz, [...]]]></description>
			<content:encoded><![CDATA[<p style="text-align: justify;">
<p style="text-align: justify;"><a href="http://www.hydrogen-fc.com/wp-content/uploads/2009/09/versmaxmicronano.jpg" rel="thumbnail"><img class="alignleft size-thumbnail wp-image-784" style="border: 1px solid black; margin: 5px;" title="versmaxmicronano" src="http://www.hydrogen-fc.com/wp-content/uploads/2009/09/versmaxmicronano-250x250.jpg" alt="" width="250" height="250" /></a>VersaMax40 is one kind of VersaMax Micro Plus Controllers from <a href="http://www.ge-ip.com" target="_blank">GE Intelligent Platforms</a> that have more enhanced features like : more memory (for boolean, integer, floating data), real time clock (RTC),  optional port for industrial protocol communication, high speed counter (HSC) up to 4 at 100kHz, pulse width modulation (PWM) up to 4 at 65kHz, motion commands, PID function and subroutines. VersaMax40 limited to 152  maximum physical I/O with up to 4 I/O expansion units.</p>
<p style="text-align: justify;">VersaMax40 have 1 RS-232 and second port option for RS-232/RS-485/USB/Ethernet. Usually, 1 RS-232 port defined as  SNP port mode for PLC programming with Proficy Machine Edition. On This application we will use second port option to add ethernet communication module &#8211; IC200UEM001. With this communication module we could self-defined VersaMax40 as Server device that communicate with HMI Ifix5.0 as Client device via Modbus TCP protocol. With ethernet communication module, VersaMax40 could handle up to 8 Clients device simultaneous on Modbus TCP network. Please following GFK-2436B for detail instruction.<span id="more-123"></span></p>
<p style="text-align: justify;"><strong>Configuring VersaMax40 with Proficy Machine Edition Software<br />
</strong></p>
<p style="text-align: justify;">To configure second port option that available on VersaMax40 for Modbus TCP protocol, we should using Proficy Machine Edition software via port 1 RS-232. Port 1 RS-232 on VersaMax40 using RJ45 connector. Below the cable connection between DB9 connector to RJ45 connector.</p>
<p style="text-align: center;"><img class="aligncenter" title="DB9_to_RJ45" src="http://www.hydrogen-fc.com/wp-content/uploads/2009/09/DB9_to_RJ45.PNG" alt="DB9_to_RJ45" width="585" height="327" /></p>
<p style="text-align: center;"><img class="aligncenter" title="DB9_to_RJ45_Table" src="http://www.hydrogen-fc.com/wp-content/uploads/2009/09/DB9_to_RJ45_Table.PNG" alt="DB9_to_RJ45_Table" width="585" height="362" /></p>
<p style="text-align: justify;"><strong>Configuring IC200UEM001 as Modbus TCP Server</strong></p>
<p style="text-align: justify;">Factory configuration for ethernet communication module &#8211; IC200UEM001 is GE Fanuc SRTP function. With these function we could setting the permanent IP address then connect Proficy Machine Edition via crossover ethernet cable to program PLC VersaMax40. To set IC200UEM001 with Modbus TCP Server function please following below  step :</p>
<ol>
<li>Connect IC200UEM001 to computer using crossover ethernet cable.</li>
<li>Replace <a href="http://www.hydrogen-fc.com/wp-content/uploads/2010/08/GEF_SRTP_V1.0.zip" target="_blank">GE Fanuc SRTP</a> with <a href="http://www.hydrogen-fc.com/wp-content/uploads/2010/08/Modbus_TCP-Server_v1.0.zip" target="_blank">Modbus TCP Server</a> firmware using <a href="http://www.hydrogen-fc.com/wp-content/uploads/2010/08/PumpKIN.zip" target="_blank">PumpKIN Utility</a> software. Following GFK2436B for detail instruction.</li>
<p style="text-align: center;"><a href="http://www.hydrogen-fc.com/wp-content/uploads/2009/09/PumpKIN-Utility.PNG" rel="thumbnail"><img class="aligncenter" title="PumpKIN-Utility" src="http://www.hydrogen-fc.com/wp-content/uploads/2009/09/PumpKIN-Utility.PNG" alt="PumpKIN-Utility" width="612" height="359" /></a></p>
<li>Open Modbus Tester (ex. Modscan) software and testing these below register :
<ul>
<li>Physical input address on VersaMax40 are %I00001 &#8211; %I00024 similar with modbus register 100001 &#8211; 100024.</li>
<li>Physical output address on VersaMax40 are %Q00001 &#8211; %Q00016 similar with modbus register 100001 &#8211; 100016.</li>
<li>Memory (unsigned integer) data on VersaMax40 are %R00001 &#8211; etc similar with modbus register 400001  &#8211; etc.</li>
</ul>
</li>
</ol>
<p style="text-align: justify;"><strong>Connect HMI Ifix5.0 to PLC VersaMax40</strong><br />
<strong> </strong></p>
<p style="text-align: justify;"><a href="http://www.hydrogen-fc.com/wp-content/uploads/2009/09/SCU.PNG" rel="thumbnail"><img class="size-thumbnail wp-image-436 alignright" style="border: 1px solid black; margin: 5px;" title="SCU" src="http://www.hydrogen-fc.com/wp-content/uploads/2009/09/SCU-250x250.PNG" alt="SCU" width="250" height="250" /></a><em>Configuring SCU Ifix5.0 :</em></p>
<ol>
<li>Click Ifix 5.0 shortcut.</li>
<li>Click SCU (System Configuration Utility).</li>
<li>Click Configure.</li>
<li>Select Enable SCADA support.</li>
<li>Find I/O Driver Name : MBE Modbus Ethernet and click Add.</li>
<li>Click Configure the I/O Driver.</li>
<li>Click Connect to MBE I/O driver.</li>
<li>Save SCU configuration.</li>
</ol>
<p><em>Configuring MBE I/O driver Ifix5.0 :</em></p>
<ol>
<li>Click Add New Ethernet Port channel and enable it.</li>
<li>Click Add New Device and enable it. Then fill the form for IP address, maximum block, timeout, addressing mode and bit mode swapping register.</li>
<li>Click Add New Block and enable it. Then spit each type modbus register.  These is an <a href="../wp-content/uploads/2009/09/MBE-Configuration.MBE" target="_blank">exampl</a>e of MBE I/O driver configuration.</li>
<li>Save MBE I/O driver configuration and close all Ifix5.0 application.</li>
</ol>
<p><img class="aligncenter size-full wp-image-439" title="MBE Configuration" src="http://www.hydrogen-fc.com/wp-content/uploads/2009/09/MBE-Configuration.PNG" alt="" width="638" height="551" /></p>
<p style="text-align: justify;"><a href="http://www.hydrogen-fc.com/wp-content/uploads/2009/09/Database-Manager.PNG" rel="thumbnail"><img class="size-thumbnail wp-image-443 alignright" style="border: 1px solid black; margin: 5px;" title="Database Manager" src="http://www.hydrogen-fc.com/wp-content/uploads/2009/09/Database-Manager-250x250.PNG" alt="Database Manager" width="250" height="250" /></a></p>
<p style="text-align: justify;"><em>Configuring Database Manager Ifix5.0 :</em></p>
<ol>
<li>Click Ifix5.0 shorcut.</li>
<li>Click Application.</li>
<li>Click Database Manager.</li>
<li>Add tagname name, tagname type, I/O driver, I/O addresss.</li>
<li>Save all configuration on Database Manager.</li>
</ol>
<p style="text-align: justify;">After that, create simple animation or symbol in HMI Ifix5.0 that connected to I/O tagname. All I/O tagname are defined in Database Manager.</p>
<p style="text-align: justify;">For the information, Ifix5.0 support with Visual Basic syntax. It means  that HMI Ifix5.o support for customable HMI programming (ex.  programming database to Access, MySQL, SQL Server, etc). With this capability, you could self-programming to create HMI based on your application/project.</p>
<p style="text-align: center;">
<p style="text-align: justify;">
<p style="text-align: justify;">
<p style="text-align: justify;">
<p style="text-align: justify;">
<p style="text-align: justify;">
<div id="_mcePaste" style="position: absolute; left: -10000px; top: 2057px; width: 1px; height: 1px; overflow: hidden;">
<p style="text-align: center;"><img title="MBE Configuration" src="http://www.hydrogen-fc.com/wp-content/uploads/2009/09/MBE-Configuration.PNG" alt="MBE Configuration" width="638" height="551" /></p>
</div>
]]></content:encoded>
			<wfw:commentRss>http://www.hydrogen-fc.com/modbus-tcp-protocol-between-versamax40-and-ifix-5-0/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>