	<item>
		<title>Modbus RTU between PLC K120S and VSD Altivar-31 &amp; iG5A</title>
		<description><![CDATA[On these case, we build system with PLC K120S from LS Industrial Systems as Master device and VSD (Variable Speed Drive) Altivar-31 from Schneider Electric as 1st Slave device and iG5A from LS Industrial Systems as 2nd Slave Device. All communication between Master and Slave device performed by Modbus RTU protocol. PLC K120S with K7M-DR20U [...]]]></description>
		<link>http://www.hydrogen-fc.com/modbus-rturs-485-plc-k120s-to-vsd-altivar-31-ig5a/</link>
			</item>
	<item>
		<title>Modbus TCP between HMI Ifix5.0 and Flow Computer OMNI6000</title>
		<description><![CDATA[Our previous article had explained how to configuring Modbus TCP protocol between HMI Ifix5.0 and PLC VersaMax40. So that on these article we just explain how to create register blocks and few setup on Modbus Driver v.7.42 Ifix5.0 so that HMI Ifix5.0 as Client device could send/receive data from Flow Computer OMNI6000 as Server device. [...]]]></description>
		<link>http://www.hydrogen-fc.com/modbus-tcp-protocol-between-omni-6000-and-ifix-5-0/</link>
			</item>
	<item>
		<title>PID &amp; Alternate Control System</title>
		<description><![CDATA[PID (Proportional-Integral-Derivative) controller is control loop feedback mechanism that widely used in control system. PID calculating the error value that generated by difference between feedback Process Value (PV) and Set Point (SP) PID. When error value generating, PID controller adjusting output Measurement Value (MV) to minimize error near to zero value. Let us give some [...]]]></description>
		<link>http://www.hydrogen-fc.com/pid-close-loop-controller/</link>
			</item>
	<item>
		<title>Modbus TCP between HMI Ifix5.0 and PLC VersaMax40</title>
		<description><![CDATA[VersaMax40 is one kind of VersaMax Micro Plus Controllers from GE Intelligent Platforms that have more enhanced features like : more memory (for boolean, integer, floating data), real time clock (RTC),  optional port for industrial protocol communication, high speed counter (HSC) up to 4 at 100kHz, pulse width modulation (PWM) up to 4 at 65kHz, [...]]]></description>