Archive for the tag 'PLC/PAC'

Sep 13 2009

PID Close Loop Controller

Published under Wonderware Invensys

The fundamental concept of PID (Proportional, Integrative, Derivative) function that embedded on most controller is how the controller could adjust the Measurement Value (MV) for actuator  (control valve, inverter/motor speed drive, boiler, etc) so that difference between actual Process Value (PV) and Set Point (SP) could small enough close to zero.  When the difference between [...]

No responses yet                                                                                                               Print This Post Print This Post

Sep 02 2009

Modbus TCP Protocol between VersaMax40 and Ifix 5.0

Published under GE Intelligent Platforms

I would like share with you how to perform the modbus TCP/IP communication between Micro PLC VersaMax and HMI Ifix 5.0 from GE Fanuc Automation.  VersaMax are nano or micro PLC from GE Fanuc Automation. There are several type of VersaMax :

VersaMax Nano 10 (6 in/4 out built-in discrete I/O)
VersaMax Micro 14 (8 in/6 out [...]

No responses yet                                                                                                               Print This Post Print This Post

Mar 12 2009

Modbus TCP Protocol between ADAM-5510KW/TCP and Maple HMI5104T

ADAM-5510KW/TCP is PAC (Programmable Automation Controller) base on IEC-61131-3 standard package. IEC-61131-3 is the third part of open international standard IEC 61131 for graphical and textual PAC programming languages. Base on IEC-61131-3, PAC should support these programming languages :

Ladder Diagram (LD)
Function Block Diagram (FBD)
Structured Text (ST)
Instruction List (IL)
Sequential Function Chart (SFC)

2 responses so far                                                                                                               Print This Post Print This Post

Feb 12 2009

TCP Protocol between Wonderware ArchestrA 3.0 and SLC500

On this chapter I will show you how to configure Wonderware ArchestrA 3.0 to control and monitor 2 or more PLC SLC500 via TCP protocol. Before that, you should have already install :

Microsoft XP Professional Service Pack 2 – minimum operating system
Microsoft SQL Server 2005 Service Pack 2 – repository database when running ArchestrA application
Wonderware [...]

No responses yet                                                                                                               Print This Post Print This Post