˙˙ CPLProjectDefault Project˙˙ CPLLocationDefault Location˙˙ CMTMod MVI46-MNET"MODBUS TCP/IP COMMUNICATION MODULE MVI46-MNET1.46˙˙CPortModule˙˙˙˙˙˙ CStringObjModule+ 46MNET€ MNet Client X˙˙˙˙ €MNET Client X+ MVI MNETCR€ MNet Servers˙˙˙˙ € MNet Servers€STATIC ARP TABLE˙˙˙˙ €STATIC ARP TABLE€Comment˙˙˙˙ €Comment€Module>˙˙˙˙ €Module+ 46MNET˙˙CPSTModule+ 46MNET ˙˙˙˙Module+ 46MNET˙˙CTGSTModule+ 46MNET˙˙CTagError/Status Pointerx004955-1All error/status saved˙KStarting register location in virtual Modbus database for the error/status table. If a value of -1 is entered, the error/status data will not be placed in the database. All other valid values determine the starting location of the data. This data area includes the module version information and all server error/status data.€ M1 Write Sizex4999100049990Max register in M1EStarting DB address where read data stored. Increments of 50 words. €Failure Flag Countx00655350Communication always ONZDetermines if BP failure will disable protocol (0=Ignore, >0 = failure count to disable)€Initialize Output Data Yes/No Num110Make initializationQRead output values from controller Yes = enables option. No = disables option.€Duplex/Speed CodeDuplexSpeedCode00Speed negotiate with Prolinkg0=Auto-negotiate. 1=10MB/half-duplex. 2=10MB/full-duplex. 3=100MB/half-duplex. 4=100MB/full-duplex.€ MNet Client X>˙˙˙˙ €MNET Client X+ MVI MNETCR€MNET Client X+ MVI MNETCR ˙˙˙˙MNet Client X+ MVI MNETCRMNet Client X Commands€MNet Client X+ MVI MNETCR €Error/Status Pointerx480048004990-1Error/status capacity is 4800'Database offset for client status data.€Command Error Pointerx481048104999-1Not Used.Database offset for client command error list.€Minimum Command Delayx1010655350Timi command delay is 10 msec3Minimum number of msec's between commands (0-65535)€Response Timeoutx10001000655350Time respons delay is 1000 msec)Response message timeout (mSec) (0-65535)€ Retry Countx33100 Try 3 times#Response failure retry count (0-10)€ Float FlagYes/NoNNNot used%Use floating-point data type (Yes/No)€ Float Startx70007000655350Not Used/Register offset in message for floats (0-65535)€ Float Offsetx2000200099990Not Used$Internal Address for floats (0-9999)€ ARP Timeoutx55601Not Used˙˙˙˙ € MNet Servers€ MNet Servers ˙˙˙˙ MNet Servers€ MNet Servers€ Float FlagYes/NoNNNot used˙Yes or No This flag specifies if the floating-point data access functionality is to be implemented. If the float flag is set to Yes, Modbus functions 3, 6 and 16 will interpret floating point values for registers as specified by the two following parameters.€ Float Startx70007000655350Not used˙€0 to 65535 This parameter defines the first register of floating point data. All requests with register values greater-than or equal to this value will be considered floating-point data requests. This parameter is only used if the Float Flag is enabled. For example, if a value of 7000 is entered, all requests for registers 7000 and above will be considered as floating-point data.€ Float Offsetx2000099990Not used˙Q0 to 9999 This parameter defines the start register for floating-point data in the internal database. This parameter is used only if the Float Flag is enabled. For example, if the Float Offset value is set to 3000 and the float start parameter is set to 7000, data requests for register 7000 will use the internal Modbus register 3000.€ Output Offsetx0039990Not used˙0 to 3999 This parameter defines the start register for Modbus Command data in the internal database. This parameter is enabled when a value greater than 0 is set. For example, if the Output Offset value is set to 3000, data requests for Modbus Coil register address 00001 will use the internal database register 3000, bit 0. If the Output Offset value is set to 3000, data requests for Modbus Coil register address 00016 will use the internal database register 3000, bit 15. Function codes affected are 1, 5, and 15.€Bit Input Offsetx0039990Not used˙ů0 to 3999 This parameter defines the start register for Modbus Command data in the internal database. This parameter is enabled when a value greater than 0 is set. For example, if the Bit Input Offset value is set to 3000, data requests for Modbus Input register 10001 will use the internal database register 3000, bit 0. If the Bit Input Offset value is set to 3000, data requests for Modbus Coil register address 10016 will use the internal database register 3000, bit 15. Function code affected is 2.€Holding Register Offsetx0039990Not used˙x0 to 3999 This parameter defines the start register for Modbus Command data in the internal database. This parameter is enabled when a value greater than 0 is set. For example, if the Holding Register Offset value is set to 3000, data requests for Modbus Word register address 40001 will use the internal database register 3000. Function codes affected are 3, 6, 16, and 23.€Word Input Offsetx0039990Not used˙a0 to 3999 This parameter defines the start register for Modbus command data in the internal database. This parameter is enabled when a value greater than 0 is set. For example, if the word Input Offset value is set to 3000, data requests for Modbus Word register address 30001 will use the internal database register 3000. Function code affected is 4.€STATIC ARP TABLE>˙˙˙˙ €STATIC ARP TABLE€STATIC ARP TABLE ˙˙˙˙STATIC ARP TABLE-€STATIC ARP TABLE€ IP ADDRESSx 192.168.1.197 192.168.0.100ąThis table contains a list of static IP/MAC addresses that the module will utilized when an ARP is required. The module will accept up to 40 static IP/MAC address data sets. €HARDWARE MAC ADDRESSx00:00:BC:36:CB:00FF:FF:FF:FF:FF:FF1717ćWARNING: If the device in the field is changed, this table must be updated to contain the new MAC address for that device and download to the module. If the MAC is not changed, no communications with the module will be provided. (€Comment>˙˙˙˙ €Comment€Comment ˙˙˙˙Module Comment€Module Comment€CommentxMVI46-MNET ConfigurationPut Comment Here256MNT4WATTCP€my_ipx 192.168.1.199 192.168.0.100Same with PLC 3Default private class 3 address€netmaskx 255.255.255.0 255.255.255.0Subnet mask defaultDefault class 3 network mask€gatewayx0.0.0.0 192.168.0.1Not usedThe gateway I wish to use1.4600:0D:8D:00:2C:BD1207DDD­aă@q2 ­aă@MNET.cfgWATTCP-1-1˙˙˙˙˙˙˙˙˙˙˙˙˙˙˙˙˙˙˙˙˙˙˙˙-1-1 MVI46-MNET4K